Each subdivision was rated on the following criteria, with points awarded accordingly. The higher the number, the more sever the danger.
| Subdivision Design | |
| Ingress/Egress: | |
| -two or more primary roads | 1 |
| -one road | 3 |
| -one way in/out | 5 |
| Primary Road Width: | |
| -20' or more | 1 |
| -20' or less | 3 |
| Accessibility: | |
| -road grade 5% or less | 1 |
| -road grade 5% or more | 3 |
| -other | 5 |
| Secondary Road Terminus: | |
| -loop roads or turn-arounds 45' or more | 1 |
| -turn-arounds 45' or less | 2 |
| -deadend roads less than 200' | 3 |
| -deadend roads over 200' | 5 |
| Average Lot Size: | |
| -more than 10 acres | 1 |
| -between 1 and 10 acres | 3 |
| -less than 1 acre | 5 |
| Street Signs: | |
| -present | 1 |
| -not present | 5 |
Vegetation | |
| Fuel Type: | |
| -grass | 1 |
| -litter beneath timber | 3 |
| -brush | 5 |
| -logging slash | 10 |
| Defensible Spaces Completed: | |
| -more than 70% of homes | 1 |
| -between 30% and 70% of homes | 5 |
| -less than 30% of homes | 10 |
Topography | |
| Slope: | |
| -0 to 10% | 1 |
| -11% to 30% | 5 |
| -greater than 30% | 10 |
Fire Protection | |
| Response Time: | |
| -within 15 minutes | 1 |
| -16 to 30 minutes | 5 |
| -greater than 31 minutes | 10 |
| Water Source (Within Subdivision) | |
| -500 gpm hydrants, less than 1000' spacing | 1 |
| -draft location, dip site | 5 |
| -none of above | 10 |
| Water Source (Off Site) | |
| -20 minute round trip | 1 |
| -21 to 45 minute round trip | 5 |
| -45 minute or more round trip | 10 |
Structure Hazard | |
| Materials (Predominant) | |
| -roof and siding, no-wood | 1 |
| -wood siding, non-wood roof | 5 |
| -wood roof | 10 |
| Utilities (Gas and Electric) | |
| -all underground | 1 |
| -one above, one below ground | 3 |
| -all above ground | 10 |